Drug & Device Safety Atlas
Class II FDA device recall · Z-2172-2025

Class II — the FDA judged the product may cause temporary or medically reversible harm, with a remote chance of serious harm.

This is the FDA's risk judgment for this recall. It describes the potential of the product as a category — it does not establish that any specific unit harmed anyone. Most recalls are Class II or III.

The Drill Stop Kit is the version of the Mini Sterilizable Tray that is used to store, sterilize, verify Drill Stop length, and facilitate the mounting/removal of the Drill Stops. The Drill Stop Kit includes the Release Bracket, which is used for mounting and removing Drill Stops, as well as verifying the length of the Drill Stops via a ruler and depth markings. The Drill Stop Kit also allows for optional storage of some DLC drills. Drill Stops: The Drill Stop is a reusable (up to 30 osteotomies) hollow cylinder with retention prongs that clips onto the hub of the DLC drill, creating a stop function at the desired predetermined drill depth (6mm, 8mm, 10mm, 11.5mm, 13mm and 16mm). The Drill Stops come in two formats (Short  6-13mm depth, and Long  6-16mm depth), and in several diameters for different diameter drills.

Why it was recalled

The Drill stop kit contains incorrect components.

Is your unit affected?

The recall covers only the specific lots or serial numbers the FDA listed. Enter the lot or serial number from your product's label and we'll check it against that list.

A match means your unit may be covered — stop and call your pharmacist before doing anything. No match suggests it isn't covered, but confirm anyway: code formats vary and lists can be incomplete. Your unit not being listed does not guarantee it is safe, and being listed does not mean you have been harmed.

Show the FDA's listed lot / code information
Lot # 15006511/UDI: (10)841307125310

Recall status

Ongoing — the recall is still being carried out.

Where it was distributed

Worldwide - US Nationwide distribution in the states of AL, FL, LA, MD, NJ, NV, NY, OH, OK, TN, TX, UT, VA and the country of Japan.

Recall record

Recalling firm
Implant Direct Sybron Manufacturing LLC
Product type
Devices
Recall number
Z-2172-2025
Voluntary / mandated
Voluntary: Firm initiated
Initial notification
Letter
Origin
Westlake Village, CA
Recall initiated
2025-05-01

What to do

Check the lot/code above against your product. To confirm this record and read the FDA's full notice, see the FDA recall page. Before changing anything you take or use, ask your pharmacist or prescriber — this page does not tell you to start or stop any drug or device.

Also available: structured data (JSON-LD) · recall record (JSON)

What this is — and is not

A recall is a recorded FDA enforcement action — the FDA logged that a firm is removing or correcting a product. It does not establish that any specific unit harmed anyone, and causation is not established by a recall. The class above is the FDA's risk judgment for the product category, not a finding about your unit. This page informs and compares; it is not medical advice and never tells you to start or stop a drug or device.

To report a problem you experienced, use FDA MedWatch. Verify this record at FDA recalls · Recall Z-2172-2025 · Source: openFDA enforcement.